Built-in TA indicators
Built-in TA indicators
Section titled “Built-in TA indicators”This page lists the built-in indicators available through the bot runtime’s
host-specific ta namespace. Direct indicator calls need a program timeframe
in seconds and read the worker’s local candle history:
// @program(timeframe=60)fn main(signal): return ta.rsi(14).valueThe same built-in indicator calculator is used by workflow screener queries.
Workflow nodes use a typed ScreenerExpression for filters and can request
indicator values as columns; see
screener results in workflow programs.
Indicators
Section titled “Indicators”All indicator parameters must be positive finite numbers. Integer period parameters must be whole numbers from 1 through 2000. Output names below are the properties selected after the indicator call.
The Market Data screener server currently seeds these baseline parameter combinations:
| Indicator | Baseline parameters |
|---|---|
ema |
9, 20, 21, 26, 200 |
natr |
14, 30 |
rsi |
14 |
mfi |
14 |
cci |
20 |
mrc |
200 |
volume |
50 |
sar |
No baseline preset |
chandelierexit |
No parameters |
bollingerbands |
20 |
stoch |
14, 1, 3 |
emacross |
9, 26 |
These are screener baseline configurations, not implicit QuantFlow arguments.
Pass the parameters explicitly in a bot call or workflow screener request;
for example, ta.rsi(14).value. sar supports one positive integer parameter
or three parameters: a positive integer followed by positive acceleration and
maximum-acceleration values.
| Indicator call | Outputs |
|---|---|
ta.ema(period) |
value |
ta.natr(period) |
value, atr |
ta.rsi(period) |
value |
ta.mfi(period) |
value |
ta.cci(period) |
value |
ta.mrc(period) |
value, middle, meanline, upsmall, downsmall, upinner, downinner, upouter, downouter, upbig, downbig |
ta.volume(period) |
value, average |
ta.sar(period) or ta.sar(period, acceleration, max_acceleration) |
value, long, short, uptrend, direction, next_sar, extreme_price |
ta.chandelierexit() |
value, long, short |
ta.bollingerbands(period) |
value, average, upper, lower |
ta.stoch(period, k_period, d_period) |
value, k, d |
ta.emacross(fast_period, slow_period) |
value, fast, slow |
For ta.volume, value is the current candle’s total volume and average is
the moving average of total volume. ta.sar’s long and short outputs may
be null when that side has no value. The value output is an alias for
average in ta.bollingerbands, d in ta.stoch, the middle line in
ta.mrc, and long in ta.chandelierexit.
Candle and NTPS values
Section titled “Candle and NTPS values”The same namespace exposes the current candle fields and the current NTPS value:
close = ta.candle().closeprior_close = ta.candle()[1].closentps = ta.ntps().valueta.candle() outputs time, open, high, low, close, value,
volume, qty_buy, and qty_sell; value is an alias for close. Candle
history uses zero-based offsets, so [1] selects the previous candle.
ta.ntps().value is available only for the current candle when NTPS is
present in the runtime context; it has no historical offsets.
Timeframes and runtime scope
Section titled “Timeframes and runtime scope”Direct ta.* calls use the timeframe declared by
// @program(timeframe=<seconds>). When the worker provides more than one TA
timeframe, ta.secure selects a specific one:
five_minute_rsi = ta.secure(300, ta.rsi(14)).valueThe selected timeframe must be available in the worker context. The live bot runtime provides this TA context; native backtests do not currently provide it. See bot strategy programs for indicator event handlers and the native backtest limits.